Automatic door operator trouble shooting
| Problem |
Possible Cause |
Solution |
Figures |
| The door does not respond.
|
No AC power
|
|
![]() |
Motor have no power (LED motor light not on.) |
|
![]() |
|
Jumper 1-9, or PUSH Switch setting is incorrect.
|
|
![]() |
|
Door accidentally locked.
|
|
![]() |
|
The automation opens but doesn't close.
|
Safety contacts are open.
|
|
![]() |
The automatic close function does not respond.
|
|
![]() |
|
Safety devices are on
|
|
![]() |
|
| ˇ§REDA 1ˇ¨ , ˇ§REDA 2ˇ¨ contact s are on. |
|
||
The door automatically opens and closes by itself.
|
The sensor detects something moving.
|
|
|
The door automatically stops before reaching the preset destination.
|
The Encoder may be incorrect.
|
|
|
The AD-425S stops operating automatically when the door is interrupted for three times.
|
|
||
The input power is low.
|
|
![]() |
|
LED(Relay) indicates in the opposite status.
|
The direction of Operating Arm is incorrect.
|
|
![]() |
LED(Charge) not working.
|
Fuse burn out.
|
|
|
Wires loose |
|